GMP Requirements for Cleanrooms and Cleanroom Garments
Classification: Technical Article
Release time:2022-12-08 10:35
In recent years, China’s electronics, pharmaceutical, and bioengineering industries have experienced rapid growth, driving the concurrent expansion of their supporting sectors. With the onset of the pandemic, society’s demand for clean‑room protective equipment has become even more pressing. However, as China currently lacks a national standard for testing the dust‑free performance of cleanroom garments, product quality on the market remains uneven. In response, Jia Bolitong conducted a focused study on cleanroom apparel, drawing on the “Good Manufacturing Practice for Pharmaceuticals” and its own “Standard Operating Procedure Guide for Sterile Dressing,” which was independently developed in October 2012.
Cleanliness requirements for clean production areas and changing rooms in GMP
Cleanroom garments are essential protective equipment that prevent human contamination from compromising the cleanliness of manufacturing processes. The performance of these garments directly impacts the environmental quality of cleanrooms. Consequently, the evaluation and validation of cleanroom garment performance have become frequent topics of discussion within the pharmaceutical industry. Before delving into the performance and verification of cleanroom garments, it is first necessary to review relevant knowledge and usage guidelines pertaining to changing areas and cleanroom attire.
Good Manufacturing Practice for Pharmaceuticals (hereinafter referred to as GMP) Article 34: All personnel entering the production area shall change clothes in accordance with established procedures. The materials, design, and method of wearing work garments shall be appropriate to the nature of the work being performed and the requirements of the corresponding air cleanliness level.
Article 35 Personnel entering the clean production area shall not wear makeup or jewelry.
Article 197 During the manufacturing process, measures should be implemented to the greatest extent possible to prevent contamination and cross-contamination, such as:
(1) Manufacturing different pharmaceutical products in segregated areas;
(2) Adopt a phased production approach;
(3) Necessary airlocks and exhaust ventilation shall be provided; areas with different air cleanliness levels shall be maintained under controlled pressure differentials.
(4) The risk of contamination caused by the re‑introduction of untreated or inadequately treated air into the production area shall be minimized.
(5) In production areas prone to cross-contamination, operators shall wear protective clothing specific to that area.
China’s new GMP regulations include clear requirements for cleanroom changing areas. Accordingly, personnel access routes to cleanroom production areas must be equipped with appropriate changing facilities, tailored to the nature of production, product characteristics, and the required environmental classification of the product. Furthermore, airflow patterns should be rationally designed, pressure differentials established, and monitoring systems installed to meet the purification and changing requirements of pharmaceutical GMP. Typically, the following factors must be taken into account: the layout of changing rooms, the tiered sequence of changing stages, the specified pressure differentials in the changing area, procedures for monitoring these pressure differentials, and the design of exit pathways.
Based on years of experience and industry best practices, Jia Bilitong recommends the following typical changing‑room layout diagrams:

Note: For potent drugs, given their very low permissible airborne exposure limits, to prevent drug‑containing air from leaking out of the production area through the changing room passage, the final airlock in the changing area is designed as a positive‑pressure system, and a dedicated exit airlock is installed within the changing corridor. This exit passage is configured according to the controlled non‑graded zone ( CNC) The area is partitioned, with all air filtered through high-efficiency filters, maintaining a specified air exchange rate and pressure differential. Additionally, it is designed with negative pressure relative to adjacent rooms to prevent particulates generated during the undressing process from being carried out of the changing area by airflow. For highly sterile pharmaceutical applications, an additional room for donning sterile undergarments has been incorporated.

Note: To prevent contamination from the ambient air in the general area, the air pressure is gradually increased from the first to the third shift. The outer-clothing changing room is equipped with high-efficiency filters and maintains a specified air exchange rate, with no zoning based on control levels. CNC) Consideration. An exit channel design has been added.

Note: The airlock at the end of the changing area is designed to maintain positive pressure, and a dedicated exit passage is provided within the changing corridor. This exit passage is configured to control access across different zoning levels ( CNC) zoning: all air is filtered through high-efficiency filters, with a specified air exchange rate and pressure differential; the area is maintained at negative pressure relative to the changing room to prevent particulates generated during the changing process from being carried into the changing area by airflow.
Detailed requirements for workwear in clean production areas under GMP
The layout of the changing area is critical to the clean production zone; therefore, it is essential to ensure proper selection and standardized use of cleanroom garments.
Good Manufacturing Practice for Pharmaceuticals Article 24 Workwear and its quality shall be commensurate with the requirements of production operations and the cleanliness level of the corresponding operating area, and its design and method of wear shall adequately protect both the product and personnel. The attire requirements for each cleanroom are specified as follows:
Class D Cleanroom: Hair, facial hair, and other relevant body parts shall be covered. Appropriate work attire and footwear or shoe covers shall be worn. Appropriate measures shall be implemented to prevent the introduction of contaminants from outside the cleanroom.
Class C Cleanroom: Hair and facial hair must be adequately covered, and a mask must be worn. Work attire should consist of a one-piece garment with a tight‑fitting wrist closure or separate top and bottom garments, accompanied by appropriate footwear or shoe covers. The workwear must not shed fibers or particulates.
A/B‑grade cleanroom: All hair, including the beard and other relevant areas, must be completely covered by a hood; the hood should be tucked into the collar. A mask must be worn to prevent the release of respiratory droplets, and protective goggles should be used when necessary. Sterilized rubber or plastic gloves that do not shed particulates (such as talc) must be worn, along with sterilized or disinfected shoe covers; trouser legs should be tucked into the shoe covers, and cuffs should be tucked into the gloves.
Workwear shall be sterile, one-piece garments that do not shed fibers or particulates and are capable of capturing particles emitted from the body.
Article 26 The cleaning and handling procedures for workwear used in cleanrooms shall ensure that it does not carry contaminants and does not contaminate the cleanroom. Workwear must be washed and sterilized in accordance with the relevant operating procedures, and a dedicated laundry room is recommended.
Personnel entering the production area shall change into appropriate attire and wash their hands. The selection, design, and method of donning work garments in clean areas shall comply with the general requirements. Personnel engaged in operations involving substances that are toxic or hazardous to humans shall wear prescribed protective clothing; their dedicated work garments shall be laundered and maintained separately from those of other personnel, and cross-contamination must be prevented.

-
The Five Key Performance Features of JiaBo Cleanroom Garments
The entry of personnel and materials into a cleanroom can introduce external contaminants, with personnel themselves being a significant source of contamination. According to foreign literature, the analysis of dust sources in cleanrooms is presented in the table below, with personnel-related sources accounting for… 35%. Air sampling and analysis in cleanrooms have also revealed that the primary contaminants include microscopic skin flakes from humans, fibers from clothing fabrics, and particulates of similar nature present in the outdoor atmosphere. These findings indicate that, to achieve the required air cleanliness in a production environment, it is essential to purify both personnel and materials.
-

-
Proper aseptic gowning is the most critical and highest‑risk procedure performed before personnel enter a sterile manufacturing area. An appropriately executed aseptic gowning process effectively prevents the contamination of cleanrooms or sterile areas by high‑risk contaminants such as viruses, bacteria, particulate matter, and fibers. Inadequate gowning can allow these contaminants to be carried into the cleanroom on the surface of clean garments or through protective breaches, leading to a decline in cleanliness and potentially resulting in serious quality issues for pharmaceuticals or food products.
This stage places extremely high demands on cleanroom garments, particularly… A/B‑grade cleanroom. Based on the five key performance attributes of cleanroom garments provided by Jia Bolitong, the five defining characteristics of high‑quality cleanroom apparel are as follows:
- There is minimal fiber shedding.
- The static charge generated by friction can dissipate rapidly within a short period of time.
-
Building on this foundation, Jia Boli Tong has taken high‑quality cleanroom garments to the next level. Jia Bo‑style cleanroom suits not only deliver outstanding performance in key areas such as cleanliness, barrier protection, and antistatic properties, but also ensure durability, safety, and comfort.
- Cleanliness: Does not generate dust and does not shed fibers.
- Barrier properties: The fabric is finely woven with a low dust transmission rate, providing effective barrier protection. Particles with a diameter of 0.5 micrometers or greater effectively control human‑generated contamination in clean environments and also prevent harmful substances from the environment from harming the human body.
- Antistatic Properties: Manufactured with premium raw and auxiliary materials, this product delivers excellent antistatic performance, rapidly dissipating static electricity during operation and effectively preventing dust adhesion, thereby safeguarding product quality and safety. Additionally, it helps protect users from the hazards of alternating current.
- Durability: Made with high-quality filament fibers, it boasts excellent tensile strength and outstanding resistance to aging, ensuring that the product will… Under 121°C moist heat sterilization conditions, it can be used approximately 100 times.
- Safety and Comfort: All selected materials are high-quality virgin resins; key components are sourced from imported pharmaceutical-grade raw materials and undergo specialized processing to meet pharmaceutical‑grade certification standards, ensuring both comfort and breathability.
- The moist, warm vapor emitted by the human body can also evaporate rapidly through the surface of clothing.
- Human body dust particles are also unlikely to be released into the cleanroom through gaps.
- Fibers and auxiliary materials can withstand 121°C high‑temperature moist heat sterilization ensures resistance to aging, shrinkage, breakage, and delamination, significantly extending the service life of cleanroom products.
- Sterilization and Validation of Cleanroom Garments
-
Cleanroom garments must be regularly washed and sterilized, typically 2–3 times per week. In cleanrooms with higher cleanliness levels, the washing frequency should be determined based on the number of uses. Additionally, many companies maintain dedicated lockers for cleanroom attire, assigning each employee a numbered locker to prevent cross‑contamination. Finally, cleanroom garments should be allocated to appropriate production areas, with distinct colors and styles to minimize confusion between departments and avoid accidental mix-ups during use.
Regarding the validation of cleanroom garments, many people wonder: what exactly is being validated? Typically, validation of cleanroom garments involves visual inspection after washing and drying; assessment of the degree of dryness following drying; microbial testing to determine shelf life; verification of the garment’s particle‑emission performance; confirmation of its particle‑retention performance; and validation of the number of allowable uses, among other considerations.
Jiabulitong can provide customers with a complete set of product certifications and relevant inspection and testing reports. All marketed products meet national standards, and some even comply with EU standards. Jiabulitong consistently adheres to… Adhering to the business principles of “Quality First, Customer Supreme, and Integrity-Based,” we continuously enhance our products’ core competitiveness, delivering high‑quality products and services to our customers.
-