In the pharmaceutical industry, how should cleanroom garments be properly laundered?
Classification: Technical Article
Release time:2022-12-09 09:35
In today’s environment, where pharmaceutical quality and safety are of paramount concern, cleanroom garments play a critical role in the drug manufacturing process. As companies impose increasingly stringent requirements on these garments, their laundering has become an essential component of their reuse cycle.

The laundering of cleanroom garments must not follow conventional methods. To prevent cross-contamination during washing, packaging, and handling, strict operating procedures and protocols are required for the cleaning and management of such garments.
What are the essential requirements for cleaning cleanroom garments?
- Clean the environment :
Good Manufacturing Practice for Sterile Medical Devices As stated in Appendix B7 of YY0033-2000,
The air cleanliness class of the cleanroom for washing and drying clean workwear, as well as the final‑stage cleaning and disinfection area for dedicated workstation tools, may be one class lower than that of the production area. GB50457-2019 Standard for the Design of Cleanrooms in the Pharmaceutical Industry The Requirement of Clause 5.1.16 The air cleanliness level of the washing, drying, and finishing room for clean workwear shall not be lower than Class D.
For example, Cleanroom garments for Class B and Class C areas may be washed in the Class C area. After washing, drying, folding, sterilizing, packaging, and sealing, the garments are transferred to the Class B area.
- Professional cleaning equipment: Must use dedicated industry Industrial washing and drying equipment; cleanroom garments can be washed using stainless steel tunnel-type, dust‑free dedicated washers and dryers, with the air used for drying… Must After Efficient Filter.
- Cleaning water: Generally, the cleaning process for cleanroom garments employs treated sand-filtered water and purified water, while the rinsing stage uses water with a resistivity of at least Deionized water with a resistivity of 10 megohm-cm ; Cleanroom with dust-free purification clothing The cleaning water must be ultrapure water, not ordinary industrial water. 。 The final rinse must be performed with filtered purified water, and validation must be conducted.
4. Dedicated detergent: The detergent should… Nonionic surfactants are selected, The pH is neutral to ensure clothing Performance and service life of the garment 。

The correct washing method not only effectively removes stains but also protects fabric fibers and extends the lifespan of your clothes.
During the cleaning of cleanroom garments, the following points should be observed:
● Before laundering cleanroom garments, carefully inspect them for any tears or damage and verify that all attachments, such as buttons and zippers, are intact. Any items with defects should be repaired, replaced, or discarded.
● Regardless of whether cleanroom garments are new or used, they must be sorted first; if stains are detected, they should be removed before washing.
● Clothing from different cleanrooms must be washed separately.
“What is separate washing?” The fundamental principle of separate washing is that garments intended for different purposes or used in different areas must not interfere with one another or cause cross-contamination. The “cleanliness” of cleanroom garments encompasses two key aspects: particle control and microbial control. Particle control is primarily achieved through washing, while microbial control is mainly accomplished via sterilization. After washing, cleanroom garments must remain free from secondary contamination throughout subsequent steps, including garment assembly, handling, drying, and sterilization.
● FZ/T 80014-2012 “General Technical Specification for Cleanroom Garments” Requirements, The wash water shall be softened water and treated with at least Filtration using a 2.0 μm filter membrane. Purified water used for rinsing must be filtered through at least a 0.2 μm filter membrane. To inhibit microbial growth, the water system should be equipped with a UV sterilization unit.
● FZ/T 80014-2012 “General Technical Specification for Cleanroom Garments” Requirements, The recommended drying temperature should not exceed 60 °C Then allow it to cool gradually to prevent the fabric from being subjected to sudden temperature changes. At the same time, be sure to avoid overloading the dryer and control the drying capacity according to weight or volume.
After cleaning is completed, compared with other industries, the pharmaceutical industry’s cleanroom garment handling process includes additional steps. A disinfection and sterilization procedure.
The sterilization methods for cleanroom garments include: 121°C high-temperature sterilization, ozone sterilization, gamma-ray sterilization, ETO disinfection and sterilization , Usually adopted 121°C high-temperature sterilization in the method Moist heat sterilization method 。
1. 121°C High-Temperature Sterilization: Common high-temperature sterilization methods are divided into moist heat sterilization and dry heat sterilization, differing primarily in their sterilization mechanisms. Moist heat sterilization kills microorganisms mainly by coagulating their proteins. Dry heat sterilization, on the other hand, causes protein oxidation, denaturation, carbonization, and electrolyte concentration leading to toxicity, thereby killing microorganisms. Both methods share the same principle: they rely on high temperatures as a physical sterilization approach to eliminate microorganisms; however, certain pharmaceutical products are not suitable for this type of sterilization. Moreover, after high‑temperature sterilization, cleanroom garments may, following the first two cycles, experience… clothing clothing There is a slight… Shrinkage phenomenon.
2. Ozone sterilization: The principle of ozone sterilization relies on oxidative action to disrupt the structure of microbial cell membranes, thereby achieving disinfection. Ozone initially targets the cell membrane, altering its composition… Ingredients Damage leads to metabolic dysfunction; ozone continues to penetrate the membrane, disrupting intramembranous lipoproteins and lipopolysaccharides, altering cellular permeability and resulting in cell lysis and death. 。
3. Gamma rays Sterilization During irradiation, gamma rays penetrate the sterilized protective garments and act upon microorganisms, directly or indirectly disrupting their nucleic acids, proteins, and enzymes, thereby killing the microorganisms and achieving disinfection and sterilization.
4. ETO sterilization and disinfection: It can inactivate a wide range of microorganisms, including bacterial vegetative cells, spores, viruses, and fungal spores, and is a… Extensive A broad-spectrum disinfectant. It inhibits the normal chemical reactions and metabolism of bacterial proteins. , thereby causing microbial death.
As is well known, humans are the primary source of contamination in cleanrooms. Cleanroom garments serve as a critical barrier to prevent the release of particulates from the human body, and their performance directly impacts the environmental quality of the cleanroom. In addition to proper laundering practices, selecting professional, appropriately designed cleanroom apparel is a key priority for pharmaceutical companies.