Laboratory Management in Pharmaceutical Enterprises under the GMP System


Classification: Technical Article

Release time:2023-01-03 10:06

High-quality raw materials, advanced processes and equipment, and sophisticated testing methods constitute the three pillars of modern industry. Without advanced scientific testing methods, there can be no advanced product quality. From the perspective of quality management practice, whether in the early stage of quality inspection, the intermediate stage of statistical quality management, or the modern stage of total quality management, all have relied on comprehensive measurement capabilities as their technical foundation. Consequently, the laboratory is an indispensable and critical component throughout the entire pharmaceutical manufacturing process.

In the previous article, we introduced the Materials Management module, one of the six major systems under GMP inspection. This article will cover the Laboratory Management module from several perspectives: establishing a QC personnel training system; maintaining and servicing instruments; implementing raw data record management; managing laboratory OOS and OOT results; overseeing laboratory environment and hygiene; managing laboratory labeling; and handling sample management.

 

Establish a QC personnel training system

QC resources are the laboratory’s most valuable asset, a core component of its operations, and a fundamental element of its infrastructure. In terms of QC personnel management, the key areas include the following:

 

01

Reasonably allocate laboratory personnel.

 

In accordance with operational needs, laboratory personnel shall be appropriately allocated, and the laboratory must be staffed with an adequate number of management, supervisory, and testing personnel. Clear requirements for the qualifications of all categories of personnel shall be established, along with defined job descriptions and corresponding performance‑evaluation procedures. Each year, all personnel shall be assessed and graded in line with their respective job descriptions and the associated evaluation criteria.

 

02

Establish a personnel training and assessment system.

 

Establish a personnel training and assessment system and maintain comprehensive training records to ensure continuous knowledge updates and enhance professional technical capabilities, thereby meeting the demands of ongoing professional development. As needed, develop a training and qualification‑assessment matrix to deliver tailored training and evaluations for different QC personnel, accommodating the rapid evolution of business requirements. Additionally, implement multi‑skilled worker programs and backup staffing arrangements to ensure that short‑term personnel fluctuations do not disrupt operational continuity.

 

03

Establish business and technical records.

 

The laboratory shall establish personnel technical and professional records. These records shall primarily include the technical staff’s educational background, qualification certificates, details of employee training and continuing education, assessment results, skills, work experience, as well as records of research activities and awards.

 

Instrument Maintenance and Care

The maintenance and upkeep of laboratory instruments constitute an essential component of laboratory management. Proper instrument maintenance directly impacts equipment reliability, service life, and the success rate of experiments. All instruments and equipment should adhere to the principles of dedicated responsibility, regular calibration, and scheduled preventive maintenance, with corresponding operating procedures and maintenance protocols established.

 

01

Instrument Training and Authorization

 

Prior to putting the instrument into service, the laboratory must develop operating and maintenance procedures and conduct training. For instruments that require high precision, have stringent performance requirements, are complex to operate, or pose certain risks, authorized personnel must be designated to perform independent operation and maintenance.

 

02

Instrument Operation and Maintenance

 

During operation, the instrument shall be used strictly in accordance with the operating and maintenance procedures, and the “Instrument Usage Log” must be completed promptly for traceability. Users are required to thoroughly understand the structure, operating principles, functions, key operating procedures, as well as the maintenance and upkeep requirements of the equipment they are responsible for, and to perform regular maintenance. Throughout use, attention should be paid to the instrument’s storage environment to prevent environmental degradation that might exceed its specified storage conditions.

 

03

Instrument maintenance

 

If a device malfunctions, a “Out of Service” label shall be affixed to prevent its misuse. Following repair, the laboratory shall verify the instrument’s post‑repair condition, conducting accuracy checks through methods such as metrological calibration or in‑process verification. If the results meet the required criteria, the instrument may be returned to normal operation.

 

04

Management of instruments outside laboratory control

 

When instruments are sent out for external metrological calibration, loaned to others, or sent for repair—situations that place them outside the laboratory’s direct control—the laboratory shall, upon their return, verify their external condition (including accessories) and functional status, and, if necessary, confirm the instrument’s accuracy.

 

Establishing Records Management for Original Documents

GMP requires that original records be maintained promptly, truthfully, accurately, and completely, with no omissions or unauthorized alterations; the falsification or fabrication of data is strictly prohibited.

1. Identification: Must be unique and may be implemented through numbering, color coding, or other methods.

2. Storage: To facilitate access and retrieval, records shall be classified and numbered according to their content, managed through an archiving system, and subject to detailed regulations specifying the respective management teams, responsible personnel, and periodic archiving intervals for each type of record. Furthermore, clear permissions must be established for different positions regarding which records may be accessed, and procedures for staff borrowing records must be defined.

3. Protection: Moisture-proof, pest-resistant, and fire-resistant; prevents loss, damage, and spoilage.

4. Safety and confidentiality shall be ensured.

5. Electronic records shall be subject to protection and backup procedures.

6. Specify the retention period.

7. Records shall be filed with QA promptly and on a regular basis.

8. Disposal: The destruction of records shall be approved by QA in accordance with the prescribed procedures.

Establish laboratory data OOS and OOT.

Data anomalies detected in the laboratory shall be classified as OOS or OOT and investigated and tracked in accordance with the relevant SOPs. Abnormalities encountered during experiments must be addressed head-on, rather than being concealed, to ensure compliant management.

1. During experimental procedures and when recording experimental results, if the experimental outcomes or observed phenomena differ from the expected results, the experimenter must report this immediately.

2. Upon receipt of the report, the responsible person shall assist the experimental personnel in analyzing the cause. If an experimental error is identified, it must be corrected immediately; the erroneous results and the correction process shall be documented in the experimental records, and the responsible party shall sign to confirm.

3. If experimental errors render the data unusable, the error must be rectified and the experiment either supplemented or repeated after confirmation by the responsible supervisor. Incorrect experimental records may not be deleted; instead, the cause of the error, an analysis of the issue, and the proposed solution must be documented in the relevant record.

4. Cases of obvious laboratory errors and other manifest errors do not require investigation; however, the relevant procedures, observed phenomena, analytical processes, and underlying causes must be documented in detail in the original records, with the responsible person’s signature for confirmation. Original data must be retained in the same manner as usable data.

5. When the person who discovered an OOS/OOA/OOT or suspect data reports it, and upon confirmation by the responsible person, the matter shall be handled in accordance with the relevant provisions of the “Procedures for Handling OOS/OOA/OOT or Suspect Data.”

 

Laboratory Environment and Hygiene Management

1. Hygiene in the laboratory’s clean areas shall be managed by dedicated personnel, who must strictly adhere to established experimental procedures and the laboratory’s disinfection and sterilization protocols. The laboratory shall use specialized cleaning tools that are non‑shedding, easy to wash, and easy to disinfect; these tools must be properly stored and regularly disinfected. Cleaning operations must leave no死角, and a thorough weekly disinfection and cleanup should be performed.

2. Prior to use, the user shall, in accordance with the cleanroom’s disinfection and sterilization procedures, rigorously perform scientific and appropriate disinfection and sterilization of the ceiling, walls, floor, glass surfaces, doors, all instrument surfaces, the indoor space, and any items intended to be brought into the laboratory, thereby ensuring that the cleanroom environment meets the required standards. Reagents used for cleaning are to be provided by the user.

3. Laboratory personnel must keep equipment and the work area clean at all times, and after completing experiments, they should thoroughly clean the workbench. During experimental procedures, cultivate meticulous working habits to prevent splashing or atomization of experimental materials, and strictly prohibit the dripping of solutions or reagents that could contaminate or corrode floors, work surfaces, and laboratory instruments.

4. After use, biological waste, pharmaceutical raw materials, and other discarded items must be packaged on-site and transferred out through the pass-through window. All used waste must be thoroughly cleaned up, and personal belongings must be taken away.

5. Upon completion of cleaning, the instrument and laboratory usage logbook, as well as the laboratory access logbook, must be completed in detail, and all water, electricity, gas, and doors must be securely shut.

6. All cultures, tissues, body fluid specimens, or potentially infectious waste must be stored in durable, leak-proof containers and subjected to autoclaving by the facility’s dedicated sterilization personnel for safe disposal. This ensures that no release into the environment occurs during collection, processing, handling, storage, transfer, or transportation, thereby preventing secondary contamination.

7. Air purification systems and equipment shall be inspected regularly, and indoor cleanliness levels shall also be monitored on a periodic basis.

8. The basic requirements for cleaning tools are as follows:

(1) Resists shedding of fibers and particulates, thereby preventing contamination.

(2) Use it once whenever possible; otherwise, it should be washable and dryable.

(3) Cleaning tools from different areas must not be used interchangeably.

9. Equipment, pipelines, and containers used in the process shall be promptly cleaned; when necessary, they shall be rinsed with sterile water or disinfected.

10. The disinfectants used shall not contaminate equipment, materials, or finished products. Disinfectants should be changed regularly to ensure effective disinfection and prevent the emergence of resistant strains.

 

Laboratory Signage Management

Based on the different types of laboratory management objects, these objects are distinguished by attribute identifiers and status identifiers. By nature, they can be categorized into attribute identifiers and status identifiers. Attribute identifiers define the inherent characteristics of an object; they remain constant throughout the entire process and are characterized by uniqueness and traceability.

A status indicator refers to the ability of an entity to meet specified quality requirements at a given point in time. In general, it is characterized by time‑sensitivity and variability: for the same object, different statuses may apply across different time periods.

The primary objects of identification management in laboratory activities are:

 

(1) Documents, archives, records, reports;

(2) Inspection samples;

(3) Instruments and equipment, measuring instruments, and reference materials;

(4) Pharmaceuticals and reagents;

(5) Environmental Zone;

(6) Personnel;

(7) Other.

Precautions:

(1) How to establish a signage system—what content to include, how to arrange it, who will be responsible, and which stakeholders need to be identified—requires unified coordination.

(2) The label should not be excessively large, and its placement must not interfere with the equipment’s normal operation.

(3) Labels shall be inspected regularly, and expired labels shall be promptly removed and replaced, ensuring dynamic management to prevent errors and accidents.

(4) The text, graphics, and symbols used in signage should be clear and intuitive, with content that is simple and easy for users to recognize.

(5) The design of signage should be user-friendly, aesthetically pleasing, easy to read at a glance, and straightforward to understand.

(6) Properly understand the meaning of the labels to avoid errors during use. In the laboratory, all instruments and equipment, along with their associated software and reference materials, shall be clearly marked with a three‑color label indicating their status. The status label must include essential information, such as the verification/calibration date, expiration date, verifying/calibrating organization, the instrument’s unique identification number, and the user. The three colors denote: approved (green), approved for limited use (yellow), and out of service (red).

 

Laboratory Sample Management

1. Develop a sample management procedure that covers receipt, disposition, protection, storage, retention, handling, and return.

2. Sample Receiving

Verify the test request form/contract to ensure that the sample conforms to the specified requirements. Inspect the sample’s identification, volume/quantity, appearance, and packaging; document any discrepancies on the sample registration form and promptly communicate with the client.

3. Sample Number Identification

(1) In accordance with the procedural document requirements, assign a unique identifier to each sample and affix the label to the sample. Ensure that the identification number and labeling method are traceable.

(2) Sample tracking labels: Note that, depending on the sample’s status, it can be categorized into four states: pending inspection, under inspection, inspected, and retained sample.

4. Management of the sample process

(1) Identify the preservation requirements for samples, and monitor, control, and document sample storage conditions in accordance with those requirements.

(2) During the transfer process, all relevant information pertaining to the samples shall be kept strictly confidential in accordance with applicable requirements.

5. Retention and Handling of Samples

(1) The retention period for samples shall, as a priority, comply with applicable laws and regulations and customer requirements.

(2) Unless otherwise required by laws, regulations, or the customer, samples shall be retained for a period no shorter than the dispute‑resolution feedback timeframe specified in the report.

(3) Sample handling can be arranged according to the customer’s requirements, and the customer may collect the samples.

Summary

Laboratory management is a complex, system‑wide undertaking. To ensure its sound and orderly operation, it is essential to closely monitor developments in standards and policies, as well as the adoption and advancement of new technologies. This paper has only outlined selected aspects of laboratory management; enterprises should draw broader lessons from these examples, continuously refine their practices, and advance the establishment of a robust laboratory management system. By enhancing both technical capabilities and managerial excellence, they can guarantee the provision of accurate and reliable test data, thereby safeguarding the safety and quality of pharmaceutical products.

 

 

 

 

 


Online Consultation

If you have any questions or need assistance, please feel free to leave your contact information, and we’ll get in touch promptly to help resolve your issue!

Submit