Key Personnel Compliance Points Under a Sterile Contamination Control Strategy (Part 2): Personnel Training
Classification: Q&A
Release time:2023-02-06 10:30
EU GMP Annex 1, “Sterile Product Manufacturing,” first introduced the concept of a contamination control strategy (CCS), with personnel identified as one of the key control elements.
Personnel contamination control encompasses staff training, health and hygiene, and behavioral practices. As for considerations regarding behavioral practices, these were already detailed in the preceding section under the sterile contamination control strategy, specifically in “Key Personnel Guidelines (I): Behavioral Practices.” This discussion will focus instead on personnel training. Appendix 1, in Chapter 7—“Personnel”—explicitly outlines personnel training, its content, and the associated evaluation criteria.
The Importance of Personnel Training:
1. In the production of sterile pharmaceuticals, personnel represent the greatest and most difficult-to-control source of contamination.
According to relevant data, personnel‑induced contamination accounts for 80% of cleanroom contamination, equipment and tools account for 15%, and defects in the cleanroom itself and in the filters account for 5%.
2. Requirements of GMP and EU GMP regulations:
(1) Requirement from Chapter 7 of Annex 1 to the EU GMP:
Manufacturers shall ensure that there are sufficient qualified personnel who possess the appropriate qualifications, training, and experience in the production and testing of sterile products, as well as in any specific manufacturing techniques employed at the production site, to ensure that the manufacture of sterile products complies with the requirements of Good Manufacturing Practice for pharmaceuticals.
(2) Basic requirements of the 2010 Edition GMP Sterile Products Annex:
Article 20: All personnel working in cleanrooms, including cleaning staff and equipment maintenance personnel, shall undergo regular training to ensure that the handling of sterile pharmaceuticals complies with applicable requirements. Training shall cover fundamental knowledge in hygiene and microbiology. Untrained external personnel, such as contractors or maintenance workers, who need to enter cleanrooms during production shall receive particularly detailed instruction.
Guidance and supervision.
Training content for aseptic operators:
1. Good Manufacturing Practice (GMP) for Pharmaceuticals
2. Aseptic Technique
3. Cleanroom Code of Conduct
4. Basic Knowledge of Microbiology
5. Basic knowledge of hygiene (including concepts such as cleaning, disinfection, and sterilization)
6. Changing procedure, including all details of the changing process.
7. Contact Sampling Method
8. Pollution Control
9. The hazards of microbially contaminated drugs to patient safety
10. Critical Process Characteristics
11. The meanings of alert limits and action limits
Training content for sterile processing personnel on simulated operations:
1. Changing‑clothes simulation training has been conducted and verified as satisfactory; the list has been published.
2. Aseptic process simulation training on troubleshooting methods for potential shutdowns during aseptic manufacturing processes.
3. Simulation training for cleaning equipment in Class A areas to achieve a sterile level
4. Online cleaning and online sterilization, as well as simulated training for the washing, sterilization, retrieval, and transfer of work utensils and equipment.
5. All personnel working in aseptic areas shall participate in the media fill simulation test.
6. Progressive training with periodic assessments and evaluations.
With regard to the scope of personnel, Appendix 1 provides a definition in Chapter 7, “Personnel”: “All personnel working in this area, including those engaged in cleaning, maintenance, monitoring, and other activities that require access to the cleanroom, shall receive regular training.”
Evaluation criteria for personnel training:
1. Personnel working in A/B‑grade areas shall receive training in sterile gowning and aseptic practices. Compliance with the sterile gowning procedure shall be assessed and verified, and periodic re‑evaluation shall be conducted at least annually, including visual inspection and microbiological testing (monitoring sites such as the hands, arms, chest, and forehead; acceptable limits are specified in 9.30).
Attached is the content of 9.30:

Maximum limit of microbial contamination
(a) Sedimentation plates should be sampled during the operation and replaced as needed after four hours (the exposure time shall be based on validation that includes recovery‑rate studies, and it must not adversely affect the suitability of the culture medium used). A single sedimentation plate may be exposed for less than four hours.
(b) It should be noted that, for Class A, any occurrence of microbial growth must be investigated.
(c) The contact plate limit applies to Class AB equipment rooms and to surfaces of garments. Depending on the function of a Class CD area, routine change‑over procedures in Class CD areas are generally not required to be monitored.
2. Access to A/B‑grade cleanrooms for aseptic operations, or for activities that will involve aseptic procedures, should be restricted to appropriately qualified personnel who have undergone training, passed a gowning assessment, and successfully participated in an aseptic process simulation (APS) conducted in accordance with their routine duties.
3. Unauthorized personnel (such as building or maintenance contractors) shall not enter Class B cleanrooms or dynamic Class A cleanrooms. If such personnel must enter under special circumstances, the manufacturer shall establish written procedures to govern the access of unauthorized personnel to Class A/B areas and shall conduct assessments and maintain records in accordance with PQS. Authorized personnel within the manufacturer shall supervise the activities of unauthorized personnel and evaluate the impact of those activities on the cleanliness of the affected area.
4. A system for revoking personnel access to cleanrooms shall be in place, based on the ongoing assessment of adverse trends in the personnel monitoring program and/or the identification of participation in a failed aseptic process simulation. Once qualification is revoked, retraining and re‑qualification are required before the operator may be permitted to resume any aseptic activities. For personnel entering Class B cleanrooms or performing interventions in Class A cleanrooms, re‑qualification shall include successful participation in an aseptic process simulation (APS).
Contamination control is critical to ensuring the quality and safety of sterile pharmaceutical products. Among its many components, personnel contamination control is a particularly important aspect; therefore, staff training is of paramount importance. We will continue to discuss hygiene and health aspects of personnel contamination control—stay tuned.