To ensure the quality and safety of pharmaceuticals, promote high-quality development in the sector, and safeguard and advance public health, in December 2021, the National Medical Products Administration and seven other departments jointly issued the “14th Five-Year Plan for National Pharmaceutical Safety and High-Quality Development,” which sets forth the guiding principles for pharmaceutical safety and high-quality development during the 14th Five-Year Plan period, outlines five overarching principles of “upholding” and key development objectives, and establishes ten major task areas.

With the continuous advancement of pharmaceutical manufacturing technologies, GMP regulations are imposing increasingly stringent requirements on pharmaceutical production environments. To ensure the cleanliness of cleanrooms and the quality and safety of products, considerable attention is being paid to identifying contamination sources and implementing effective control measures. This article examines the primary sources of contamination in cleanrooms from the perspective of the five key elements: personnel, equipment, materials, methods, and environment.

 

person

Cleanroom personnel are the most likely source of contamination and one of the primary sources, including skin flakes and oil contamination from staff skin, dust generated during movement, and contamination carried on work garments.

1. Personnel: Staff members’ hair and skin can also contribute to contamination. Dandruff from the hair, skin flakes and sebum, saliva produced during speech, as well as everyday skincare products and perfumes, all serve as sources of contamination in cleanrooms.

2. Human behavior The dust emission rate when a person is at rest is approximately ten times lower than that during vigorous activity. Since indoor activities are rarely entirely vigorous, taking the average of these two scenarios yields an estimated dust emission rate of five times the resting level—equivalent to 5 × 10^5 particles per minute per person.

3. Work uniform The dust‑emission level of workwear is influenced not only by its style, material, and laundering method, but also by factors such as the wearer’s activities and the amplitude of their movements within the cleanroom.

 

Table 1 Dust Emission Rates of Personnel During Different Activities

IMG_256

Table 2: Human Dust Emission Rates under Different Clothing and Activities

IMG_257

 

machine

1. Production equipment :

(1) The production equipment itself may generate or release particulate matter, such as metal chips, oils, lubricants, or other solid contaminants. These particles can be released into the air through friction, wear, or other operational processes, leading to particulate contamination in the cleanroom.

(2) Certain components of production equipment may also harbor microbial contamination, and these microorganisms can enter the cleanroom via the equipment’s contact surfaces or through other pathways.

(3) Certain production equipment may use chemical substances, such as cleaning agents, solvents, or other chemicals. During operation, these chemicals can volatilize into the air, leading to chemical contamination within the cleanroom.

2. Rotating equipment

In pharmaceutical manufacturing, equipment such as active pharmaceutical ingredient (API) processing machinery, pharmaceutical grinding machines, and drug‑packaging devices are commonly used. During operation, these systems generate particulates, volatile organic compound (VOC) emissions, and static electricity, among other pollutants. Among these, pollution arising from rotating components is particularly severe: electric motors, gear‑driven parts, servo‑mechanism components, hydraulic and pneumatic actuators, switches, and manually operated equipment can all produce fine particles due to friction between moving surfaces.

 

material

1. Materials : Materials entering the cleanroom may themselves carry contaminants such as particles, fine dust, bacteria, and fungi. These contaminants can be released into the air during the handling, conveyance, storage, and use of raw materials, leading to particulate contamination within the cleanroom. Pre‑cleaning procedures for incoming materials, the locations and methods for unpacking, as well as the protocols for entry into the cleanroom, should all be carried out in accordance with the relevant cleanroom operation and management standards.

2. Widget : Small components are another major source of contamination in the manufacturing process, yet they are often overlooked. Even when operations are conducted in strict accordance with relevant standards and procedures, it is impossible to completely prevent contaminants from adhering to equipment, materials, and packaging—particularly when small parts that are difficult to clean thoroughly enter the cleanroom.

 

Law

1. Process Operation:

In the pharmaceutical industry, dust-generating process operations include mixing, grinding, powder handling, drying, tableting, and packaging. To control dust generation and dispersion, pharmaceutical companies typically implement a range of measures, such as using enclosed equipment and systems, installing dust collection devices, conducting regular cleaning of equipment and work areas, and providing employees with personal protective equipment.

2. Precautions:

When performing dust-generating process operations, personnel should observe the following precautions:

(1) Wear appropriate work attire and protective equipment, such as gloves, masks, and goggles, to ensure your personal safety.

(2) Observe operating procedures and perform work in accordance with the standard operating process.

(3) Avoid mixing production and living areas to prevent cross-contamination.

(4) Regularly maintain equipment and clean production areas to minimize the presence of dust and contamination.

(5) Pay attention to ambient temperature and humidity to control dust generation and product quality.

(6) Conduct regular testing and maintenance of the cleanroom to ensure that the production environment meets the required standards.

 

ring

1. Unfiltered wind

For newly constructed or renovated cleanrooms in pharmaceutical manufacturing facilities, as well as when replacing final‑stage filters, rigorous acceptance testing must be conducted in accordance with relevant industry standards. This testing verifies that there are no leaks at the interface between the HEPA filter and its supporting frame, and any identified leaks must be addressed to prevent unfiltered supply air from entering the cleanroom and causing contamination.

It should be noted that, during production, if operations are not conducted in accordance with established professional standards—resulting in contact with the fragile HEPA filter media—or if the HEPA filter support frame is compromised by vibration, aging of the sealing gasket, or other factors, the sealing performance may deteriorate. This can allow unfiltered air to enter the cleanroom, thereby contaminating it; such scenarios must be treated as critical control points in routine monitoring activities.

2. Cleanroom surface

The dust generation rate of cleanroom surfaces is also a critically important parameter. Studies have shown that approximately 8 square meters of floor surface generates roughly the same amount of airborne particles as one person at rest.

Floors, walls, ceilings, and other surfaces within cleanrooms all constitute sources of contamination, with contamination primarily arising from human contact or airborne deposition. Building materials and finishes may also emit harmful substances; the use of low‑quality materials can lead to cracking, releasing fibers, wood dust, gypsum, and other particulates, thereby becoming additional sources of contamination.

3. Adjacent contaminated areas

Areas adjacent to cleanrooms can also be regarded as sources of contamination, including lower‑class clean areas and non‑clean areas. Contaminants carried by personnel and by the entry and exit of production raw materials constitute another significant source of pollution affecting cleanrooms. Dust and microorganisms originating in these adjacent areas may enter the cleanroom via the ventilation system, compromising the cleanroom environment and, consequently, impacting pharmaceutical manufacturing processes and product quality.

Therefore, in the design and operation of pharmaceutical cleanrooms, it is necessary to consider the contamination levels in adjacent areas and implement appropriate measures for contamination control and protection.

 

The maintenance and management of cleanrooms is a systematic and complex undertaking; only by identifying the sources of contamination can targeted preventive and control measures be implemented. We will continue to explore the various strategies for contaminant control in cleanrooms, so please stay tuned.